Control Panels
1. USB Connection A (Host)
2. Power Switch
3. Wire Feed Speed Sensor Conn. (Optional)
4. Gas Flow Sensor Connection (Optional)
5. 115 VAC, 10 A Duplex Receptacle
6. Circuit Breakers
7. Ethernet Connector A
8. Ethernet Connector B
9. Network Feeder Connector
1. Voltage/Arc Adjust Display Meter
2. Program Display
3. Program # Select
4. Process Setup Button
5. Control Knob
6. Trigger Receptacle
7. On/Off Switch
8. Voltage/Arc Adjust Button
9. Wire Feed Speed/Arc Control Setup Button
10. Wire Speed/Amperage Display Meter
11. Feeder Setup Button
12. Jog/Purge Switch
Front Panel Rear Panel
Axcess E Feeder and
Remote Operator Interface (ROI E)
Capabilities
Dual Schedule — Toggle between two program
pairs (e.g. 1,2 – 3,4 – 5,6 – 7,8).
4T — When trigger is released, output will
operate at different weld parameters.
Trigger Program Select (TPS) — Provides the
ability to access any of the Multi-MIG
®
processes or any of the eight active programs.
Trigger Dual Schedule (TDS) — When activated
allow selection between predetermined program
pairs (e.g. 1,2 – 3,4 – 5,6 – 7,8).
Trigger Hold (TH) — When activated, allows gun
trigger release and continuous welding until
trigger is pulled again.
Carbon Arc Gouging (CAC-A) — Can be activated.
Sequence
Preflow: 0.1 –10.0 seconds
Start Power: 0.1 –10.0 seconds
Crater: 0.1 –10.0 seconds
Postflow: 0.1 –10.0 seconds
Arc Adjust — Arc length (Trim)
Arc Control — Arc force or focus (SharpArc
®
)
Process Selection — Accu-Pulse
®
,
Accu-Curve
™
, Pulsed MIG, MIG, Metal-Cored
Kommentare zu diesen Handbüchern